Ecoal (esterownik.pl) static fuel boiler and pump controller (#18480) - matkor
* Starting work on ecoal boiler controller iface. * Sending some values/states to controller. * Basic status parsing, and simple settings. * Platform configuration. * Temp sensors seems be working. * Switch from separate h/m/s to datetime. * Vocabulary updates. * secondary_central_heating_pump -> central_heating_pump2 * Pumps as switches. * Optional enabling pumps via config. * requests==2.20.1 added to REQUIREMENTS. * Optional enabling temp sensors from configuration yaml. * autopep8, black, pylint. * flake8. * pydocstyle * All style checkers again. * requests==2.20.1 required by homeassistant.components.sensor.ecoal_boiler. * Verify / set switches in update(). Code cleanup. * script/lint + travis issues. * Cleanup, imperative mood. * pylint, travis. * Updated .coveragerc. * Using configuration consts from homeassistant.const * typo. * Replace global ECOAL_CONTR with hass.data[DATA_ECOAL_BOILER]. Remove requests from REQUIREMENTS. * Killed .update()/reread_update() in Entities __init__()s. Removed debug/comments. * Removed debug/comments. * script/lint fixes. * script/gen_requirements_all.py run. * Travis fixes. * Configuration now validated. * Split controller code to separate package. * Replace in module docs with link to https://home-assistant.io . * Correct component module path in .coveragerc. More vals from const.py. Use dict[key] for required config keys. Check if credentials are correct during component setup. Renamed add_devices to add_entities. * Sensor/switch depends on ecoal_boiler component. EcoalSwitch inherits from SwitchDevice. Killed same as default should_poll(). Remove not neede schedule_update_ha_state() calls from turn_on/off. * lint fixes. * Move sensors/switches configuration to component setup. * Lint fixes. * Invalidating ecoal iface cache instead of force read in turn_on/off(). * Fail component setup before adding any platform entities. Kill NOTE. * Disallow setting entity names from config file, use code defined default names. * Rework configuration file to use monitored_conditions like in rainmachine component. * Killed pylint exception. Log error when connection to controller fails. * A few fixes. * Linted.
Showing
- .coveragerc 3 additions, 0 deletions.coveragerc
- homeassistant/components/ecoal_boiler.py 98 additions, 0 deletionshomeassistant/components/ecoal_boiler.py
- homeassistant/components/sensor/ecoal_boiler.py 63 additions, 0 deletionshomeassistant/components/sensor/ecoal_boiler.py
- homeassistant/components/switch/ecoal_boiler.py 85 additions, 0 deletionshomeassistant/components/switch/ecoal_boiler.py
- requirements_all.txt 3 additions, 0 deletionsrequirements_all.txt
Loading
Please register or sign in to comment